Welcome to the Australian Ford Forums forum. You are currently viewing our boards as a guest which gives you limited access to view most discussions and inserts advertising. By joining our free community you will have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features without post based advertising banners. Registration is simple and absolutely free so please, join our community today! If you have any problems with the registration process or your account login, please contact us. Please Note: All new registrations go through a manual approval queue to keep spammers out. This is checked twice each day so there will be a delay before your registration is activated. |
|
|
Thread Tools | Display Modes |
28-03-2016, 11:33 PM | #1 | ||
Starter Motor
Join Date: Mar 2016
Posts: 21
|
2.3 litre petrol Zetec MA mondeo,Thermo fan run very fast after turn engine off . The Thermo fan will run for about 30 seconds then completely turns fans off,which is correct .This is after car running normal speed around country road. These fans fast cool down and run ridiculously fast for 30 or 40 seconds. I not sure at time but after removing foam at top of radiator and take trim rubber around radiator seems to reduce need for fan running fast after engine turned off. I gather for Australia the radiator not big enough for our conditions for radiator very thin . Air cond condenser restrict air flow to much to radiator for fins are very thin. I clean but very few insects on there. It really under cooled. This symptom seem to be normal for it done from when new . The dealer couldn't find any fault code . They agree it did seem strange the Thermo single fan was running fast when I pulled up for service . It be better they had 2 cooling fans or put bigger radiator in.
|
||
29-03-2016, 01:42 AM | #2 | ||
Challenge Accepted!
Join Date: Jan 2006
Location: Under the Southern Cross
Posts: 882
|
there's nothing wrong with the setup, except the fanspeed controller being part of the shroud. I drove 620km with my fan failed. Family of 5, boot 1/2 filled 40Deg day. Engine temp stayed where it always is, only the A/C tripped out often from over temp.
Had a new one fitted at the Holiday destination and it's much quieter when in use, I don't even notice it running most of the time unless it's doing a dpf regen. Other than that I don't notice high speeds of any sort. Now thinking about it perhaps when the AC is on at shut down (which I don't usually do). |
||